Mining conveyor-belt replacement
Start from the complete existing belt specification and route conditions.

Model / STH1800
STH1800 steel-cord belt listed at 1800 N/mm in the STH schedule. Confirm breaker layers, working tension and pulley conditions before specifying the belt and splice.

| Field | Catalogue value |
|---|---|
| Model | STH1800 |
| Tensile Strength (N/mm) | 1800 |
| Tensile Range (N/mm) | 225 |
| Tensile Range (PIW) | 1285 |
| Warp Cord Diameter (mm) | 3.70 |
| Warp Cord Pitch (mm) | 7.6 |
| Pulley Diameters @100% | 800 |
| Pulley Diameters @60% | 630 |
| Pulley Diameters @30% | 500 |
| Pulley Diameters Snubs | 400 |
| Width mm | Tolerance mm | Cord count for STH1800 |
|---|---|---|
| 650 | -7/+10 | 82 |
| 762 | -8/+10 | 96 |
| 800 | -8/+10 | 101 |
| 914 | -9/+10 | 115 |
| 1000 | ±10 | 126 |
| 1067 | ±10 | 135 |
| 1200 | ±10 | 152 |
| 1220 | ±10 | 155 |
| 1372 | ±12 | 174 |
| 1400 | ±12 | 178 |
| 1524 | ±12 | 194 |
| 1600 | ±12 | 204 |
| 1676 | ±14 | 214 |
| 1800 | ±14 | 230 |
| 1828 | ±14 | 233 |
| 1981 | ±14 | 254 |
| 2000 | ±14 | 256 |
| Source option / property | Catalogue entry |
|---|---|
| One layer · weft cord diameter mm | 1.5 |
| One layer · weft cord pitch mm | 6 |
| One layer · minimum top cover mm | 5.5 |
| One layer · minimum bottom cover mm | 4.0 |
| Two layers · weft cord diameter mm | 1.5 |
| Two layers · weft cord pitch mm | 8 |
| Two layers · minimum top cover mm | 5.5 |
| Two layers · minimum bottom cover mm | 5.5 |
| Constant-load elongation as printed | 0.4–0.6% |
. Catalogue values are not batch test results or an approved quotation
The parent series gives the one-/two-layer breaker options and width matrix. Confirm which configuration is required; nominal strength alone does not settle the covers or splice.
Source pulley values are based on the stated tension-range percentage at safety factor 8, not every conveyor operating condition.
Provide belt width, length, cover grade, breaker layers, pulley sizes, working tension, startup conditions, splice drawing and document requirements.
These are catalogue references, not batch results, compliance certification or confirmation of every available size combination. Request the quotation-specific construction, drawing and acceptance documents
One- and two-layer anti-rip options are separate source constructions; confirm the selected covers, weft arrangement and actual dimensions. The pulley rows do not print their diameter unit; request the controlled unit/drawing. Width rows marked / are not inferred or filled as zero.
Start with the STH1800 source tables and download the matching catalogue extract. Read the STE/STH pulley-schedule guide, then compare the one- and two-layer breaker options against the existing conveyor and splice drawing. Identify the required controlled documents before preparing an enquiry with the complete designation, dimensions and operating conditions. This is a specification-review example; final suitability still requires technical confirmation.
Start from the complete existing belt specification and route conditions.
Review heat exposure and conveying duty before comparing offered constructions.
Check conveying duty and safety-document requirements separately.
Formal TDS revision, batch report and certification original: pending confirmation for the selected product and order.
These are complete catalogues. Use the product and physical-page references below. They are not single-model datasheets, approved drawings, batch test reports or certification originals. Different catalogue schedules and versions must not be combined.
Full source catalogue for reference only. Check the physical pages and the selected construction. Catalogue claims do not replace order-specific technical approval, test results or certification evidence.
File version: 46905d537347 · 41 PDF pages. Issue date: not confirmed.
Cord dimensions, spacing, cover construction and splice requirements also need to match.
Provide the project specification, belt schedule, conveyor arrangement and required splice details.
Provide the conveyor layout, selected breaker configuration, operating tension and splice drawing before using the source pulley schedule.
Check the selected breaker configuration, operating tension, width, conveyor layout and splice drawing before applying the pulley schedule.
Compare transverse-cord spacing and the required top and bottom covers in their separate source columns. Select the configuration against the actual duty and approved construction drawing; the STH1800 strength designation does not define interchangeable constructions.
The source uses percentages of its tension range at safety factor 8, and the pulley rows omit a diameter unit. Confirm the unit and controlled drawing together with working tension, startup conditions and pulley function before selecting installation dimensions.
The downloadable CSV reproduces the identified catalogue data. Request the selected construction datasheet, approved equipment/splice drawing and applicable original test or certification evidence. These documents remain to be verified; catalogue entries alone do not establish batch results or supplier approvals.
Send the complete designation and source version, breaker option, belt width and length, covers, material and loading conditions, working tension, startup conditions, pulley arrangement and splice drawing. Identify the documents and acceptance requirements needed for your project.
Browse all questions for this product, including selection guides →
NEXT STEP / PRODUCT ENQUIRY
STH1800 Steel Cord Conveyor Belt
This product is included automatically. Tell us your application, required dimensions or what you need to verify. Leave unknown details for review.
Open the full enquiry page →