GRAND RUBBER — Engineered for Endurance
HomeAbout UsBuyer SupportFAQWorksheetSearchMarkets / EN

Model / STH2000

Steel Cord Conveyor Belt

STH2000 steel-cord belt listed at 2000 N/mm in the STH schedule. Confirm breaker layers, working tension and pulley conditions before specifying the belt and splice.

Series construction reference: Steel Cord Conveyor Belts; not an individual model photograph
Series construction reference: Steel Cord Conveyor Belts; not an individual model photograph

Specifications & construction

Model specifications
FieldCatalogue value
ModelSTH2000
Tensile Strength (N/mm)2000
Tensile Range (N/mm)250
Tensile Range (PIW)1430
Warp Cord Diameter (mm)3.80
Warp Cord Pitch (mm)7.2
Pulley Diameters @100%800
Pulley Diameters @60%630
Pulley Diameters @30%500
Pulley Diameters Snubs400
Selected-model width tolerance and cord count
Width mmTolerance mmCord count for STH2000
650-7/+1086
762-8/+10101
800-8/+10106
914-9/+10121
1000±10133
1067±10142
1200±10160
1220±10163
1372±12183
1400±12187
1524±12204
1600±12214
1676±14225
1800±14241
1828±14245
1981±14266
2000±14268
Selected-model breaker options
Source option / propertyCatalogue entry
One layer · weft cord diameter mm1.5
One layer · weft cord pitch mm6
One layer · minimum top cover mm5.5
One layer · minimum bottom cover mm4.0
Two layers · weft cord diameter mm1.5
Two layers · weft cord pitch mm8
Two layers · minimum top cover mm5.5
Two layers · minimum bottom cover mm5.5
Constant-load elongation as printed0.4–0.6%

. Catalogue values are not batch test results or an approved quotation

Application & ordering review

Construction and acceptance boundary

The parent series gives the one-/two-layer breaker options and width matrix. Confirm which configuration is required; nominal strength alone does not settle the covers or splice.

Pulley conditions

Source pulley values are based on the stated tension-range percentage at safety factor 8, not every conveyor operating condition.

Prepare an enquiry

Provide belt width, length, cover grade, breaker layers, pulley sizes, working tension, startup conditions, splice drawing and document requirements.

Source and evidence scope

These are catalogue references, not batch results, compliance certification or confirmation of every available size combination. Request the quotation-specific construction, drawing and acceptance documents

Source option and unit boundary

One- and two-layer anti-rip options are separate source constructions; confirm the selected covers, weft arrangement and actual dimensions. The pulley rows do not print their diameter unit; request the controlled unit/drawing. Width rows marked / are not inferred or filled as zero.

Continue your product decision

Operating scenarios connected to this product

Other entries in this series — compare separately

Documents & buyer guidance

Formal TDS revision, batch report and certification original: pending confirmation for the selected product and order.

Catalogue PDF references

These are complete catalogues. Use the product and physical-page references below. They are not single-model datasheets, approved drawings, batch test reports or certification originals. Different catalogue schedules and versions must not be combined.

Request matching technical files

Product FAQ

Are equal ST ratings enough to identify a replacement?

Cord dimensions, spacing, cover construction and splice requirements also need to match.

What should an EPC inquiry include?

Provide the project specification, belt schedule, conveyor arrangement and required splice details.

What information should I provide for STH Steel Cord Conveyor Belts?

Provide the conveyor layout, selected breaker configuration, operating tension and splice drawing before using the source pulley schedule.

Can the STH pulley reference be used without the conveyor drawing?

Check the selected breaker configuration, operating tension, width, conveyor layout and splice drawing before applying the pulley schedule.

What information should I provide for STH2000 Steel Cord Conveyor Belt?

Provide the STH2000 conveyor layout, breaker option, working tension and splice drawing to check the catalogue pulley basis.

Browse all questions for this product, including selection guides →

Catalogue model comparison

Compare dimensions and pattern only; suitability still needs an application review. Up to three models.

Specifications, duty & approval inputs

Compare & pass on the review

Open a shareable catalogue comparison

NEXT STEP / PRODUCT ENQUIRY

Discuss your requirements

STH2000 Steel Cord Conveyor Belt

This product is included automatically. Tell us your application, required dimensions or what you need to verify. Leave unknown details for review.

Open the full enquiry page →
Add technical conditions, company or attachment (optional)
Project market & document requirements (if known)

Requested requirements are subject to review. English is the current website language; a language request does not confirm translation or local support availability.

Local preview: submissions are saved on this computer. Email delivery and CRM are not connected.